Ametek-Jofra ETC-400A Dry Block Calibrator (28 to 400 Deg C)

Ametek-Jofra ETC-125A Dry Block Calibrator

Ametek-Jofra ETC-400A Dry Block Calibrator (28 to 400 Deg C)


Ametek Jofra ETC-400A
Dry Block Temperature Calibrator




The Ametek ETC could be the world's fastest Dry Block Calibrator!

The Ametek Jofra ETC Dry Block heats up by up to 100 Deg C/212 Deg F per minute and completes a full dual-point test in less than 10 minutes, including stability time; timesavings at your fingertips! The ETC- series is designed for field testing of temperature measurement devices. The small size and light weight make it a perfect instrument to verify sensors in difficult to reach places. All JOFRA ETC units have many of the same useful and timesaving features offered in the more advanced JOFRA dry-block series.

FEATURES:

Designed for people
who perform tests and verifi cations of temperature sensing devices in the field. This instrument is ideal when time is a critical factor and the highest accuracy is not a critical factor.

Reduced size and weight
are important considerations because the unit is able to fi t into a tool box or instrument carrying case and can be used for sensors that are difficult to access.

One-key-one-function user interface
provides immediate access to setting the temperature and the auto-step timesaving function. There is no need for
manipulation of sophisticated menus.

The Stability indicator provides
audible and visual prompts when
the temperature is stable. This
function also includes a 3 minute
countdown before the stable
condition.


Stainless steel
and rubber side panels make the instrument suitable for many years of faithful duty in an industrial environment.

Super fast heating - ETC-400A dry-block The ETC-400 A is designed for optimum speed. The heating block is built around a highly efficient heating element. The insertion holes for the temperature device under test are located around this element. To reduce mass and increase effectiveness, there is no removable insertion tube; the holes are drilled directly into the block. The minimal mass offers an extremely fast heating and cooling time. The different layouts also make it possible to use an external reference probe during the calibration.

Choose the combination of holes that best suits your needs from our various design combinations.

If your application requires a dry-block that can handle large sensors or more than one sensor at a time, we offer several other JOFRA dry-block calibrators that can meet your needs.

Easy-to-use, intuitive operation - All instrument controls are accessed directly from the front panel. The main functions on the ETC- series are designed with one-key-one-function logic. This means that there are no difficult multiple keystrokes to remember to access primary functions. The easy-to-read, backlit display features dedicated icons, which help in identifying instrument conditions and operational steps.

Set temperature - The Up and Down arrow keys allow the user to set the exact temperature desired with a resolution of 0.1 Deg C or Deg F.

Stability indicator -
The bold checkmark on the display indicates that the calibrator has reached the desired set temperature and is stable. The operator may change the stability criteria and establish a greater level of confidence in the calibration results as desired. A convenient countdown timer is activated three minutes before the unit reaches stability. This prompts you to be prepared to record results.



Auto-stepping -
This feature saves time. The operator may stay in the control room, or another remote location, monitoring the output from the sensor-under-test while the ETC- series calibrator is placed in the process and automatically changes the temperature using a programmed step value and rate. Up to 9 different temperature steps may be programmed, including the hold time for each step. This feature is also ideal for burning-in new sensors prior to installation; this minimizes initial drift and allows for initial testing. It is also useful for testing temperature data loggers.

Maximum temperature - From the setup menu, you can select a lower maximum tempe-rature limit for the calibrator. This function prevents damage to the sensor-under-test caused by the application of excessive temperatures.

Instrument setups - The ETC-series stores the complete instrument setup, including: engineering units, stability criteria, resolu-tion, auto-step settings, and maximum temperature.

Re-calibration/adjustments made easy - The ETC- series has a very easy and straightforward procedure for re-calibration/adjustment. There is no need for a screwdriver or PC software. The only thing you need is a reliable reference thermometer. Place the probe in the calibrator and follow the instructions on the display.



Simplified calibration documentation
All JOFRA ETC- instruments are supplied with RS232 computer interface and the calibration software AMECAL-LIGHT for on-line use. This WINDOWS ®-based software allows the user to customize his or her calibration routines. The software is easy to use so you do not have to be a programmer to configure your own
calibration procedures. After calibration you can print out certificates that contain all necessary information for your ISO-9000 or similar quality systems.
The ETC calibrator can also work with the larger AMECAL-TEM-PERATURE software, which supports automatic calibration for all JOFRA dry-block calibrators equipped with an RS-232 serial data interface including the JOFRA DTI-1000 digital thermome-ter. For semi-automatic calibrations, the software also supports liquid baths, ice points,
or other dry-block heating and cooling sources. Using the software's »SCENARIO« function allows for combining instruments in virtually any configuration.

SPECIFICATIONS:

AMETEK-JOFRA
DRY BLOCK MODELS
Spec's at 23 Deg C

ETC 125 A

ETC 400 A


ETC 400 R
IR Calibrator

Minimum Temp

-10 Deg C
-14 Deg F

28 Deg C
82 Deg F

28 Deg C
82 Deg F

Maximum Temp

125 Deg C
257 Deg F

400 Deg C
752 Deg F

400 Deg C
752 Deg F

Heating Time

Ambient to
100 Deg C
212 Deg F
11 minutes

Ambient to
maximum
5 minutes

Ambient to maximum
5 minutes

Instrument Weight

1.8 kg
3.9 lb

1.6 kg
3.5 lb

1.7 kg
3.7 lb

Instrument Size
LxWxH

172x72x182 mm
6.8x2.8x7.2 in.

172x72x182 mm
6.8x2.8x7.2 in.

172x72x182 mm
6.8x2.8x7.2 in.

Stability

0.05 Deg C
0.09 Deg F

0.15 Deg C
0.27 Deg F

0.3 Deg C
0.54 Deg F

Accuracy

0.5 Deg C
0.9 Deg F

0.5 Deg C
0.9 Deg F

0.5 Deg C
0.9 Deg F

Immersion Depth

110 mm / 4.3 in.

105 mm / 4.1 in.

-

Reference Probe
Port Size

-

-

3 mm hole for external
reference probe

Dry Well Sizes
ETC125A Type 01

12.5 - 8 - 6 - 4 mm

-

-

Dry Well Sizes
ETC125A Type 02

1/2 - 3/8 - 1/4 - 5/32 in.

-

-

Dry Well Sizes
ETC400A Type 11

-

1/16 - 1/8 - 5/32 - 1/4 - 3/16 in.

-

Dry Well Sizes
ETC400A Type 12

-

1/16 - 3/16 - 3/8 - 1/4 - 1/8 in.

-

Dry Well Sizes
ETC400A Type 21

-

2 - 3 - 4 - 4 - 6 mm



Price: $1,295.00
Buy Product Online | Visit Store Home
 
Manufactured by Ametek (JOFRA)

  Related Products


  Hard Instrument Carry Case - Hard Instrument Carry Case with Pluck Foam to fit your instruments. 100's of sizes & styles available. Call for Details


 Other Items from Dry Block Style Temperature Block

  Ametek-Jofra ETC-400A Dry Block Calibrator (28 to 400 Deg C) - Ametek-Jofra ETC-400A Dry Block Calibrator (28 to 400 Deg C)
  Ametek Jofra ETC-125A Dry Block Calibrator (-10 to 125 Deg C) - Ametek Jofra ETC-125A Dry Block Calibrator (-10 to 125 Deg C)
  Hart Scientific 9142 Field Metrology Well - Field Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate.
  Hart Scientific 9143 Field Metrology Well - Field Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate.
  Hart Scientific 9144 Field Metrology Well - Field Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate.
  Hart Scientific 9100 HDRC Dry Block Calibrator - Hart Scientific 9100 HDRC Dry Block Calibrator (33 to 300 Deg C)
  Hart Scientific 9102 Dry Block Calibrator - Hart Scientific 9102 -10 to 122 C Dry Block Calibrator
  Techne CE-350 Dry Block Calibrator - Techne CE-350 Dry Block Temperature Calibrator
  Hart Scientific 9141 Dry-Well Calibrator - If you have been using dry-well calibrators for field work, you know there is a lot more to a dry-well than its temperature range and stability. Size, weight, speed, convenience, and software are also significant.
  Hart Scientific 9140 Dry-Well Calibrator - If you have been using dry-well calibrators for field work, you know there is a lot more to a dry-well than its temperature range and stability. Size, weight, speed, convenience, and software are also significant.
  Hart Scientific 9103 Field Dry-Well Calibrator - If you have been using dry-well calibrators for field work, you know there is a lot more to a dry-well than its temperature range and stability. Size, weight, speed, convenience, and software are alsosignificant.

 

  Return To CalibratorDepot.com - Calibrator Depot sells calibrators calibration service NIST traceable calibrations metrology instruments

 

 

Please call (732) 632-6400 for Assistance or a Quote
©
www.calibratordepot.com

Store Home  |  Company Info  |  Contact Us  |  Customer Login  |  View Cart |  FAQ |  Search |  Browse All Products
shopping carts
Shopping cart powered by MonsterCommerce e-commerce software.