Fluke 53 Series II Data Logging Digital Thermometer
Fluke 50-II Thermometer Family
The new Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3 C) in a rugged, handheld test tool. Features (All Models): Large Backlit Dual Display Relative Time Clock on MIN, MAX, and AVG Electronic Offset Function Improves Overall Accuracy Measures J, K, T, and E-types of Thermocouples Readout in C, F, or Kelvin (K) Splash and Dust Resistant Case Protected by Impact Absorbing Holster User-friendly Front Panel Sleep Mode Increases Battery Life to 1000 Hours Separate Battery Compartment 3 Year FLUKE Warranty
The Fluke 53 Series II and 54 Series II Also Include: Data Logging up to 500 Points of Data User Adjustable Recording Interval Also Read Type R, S, and N Thermocouples Real Time Clock Captures the Exact Time of Day when Events Occur Recall Function Allows Logged Data Review IR Communication Port Allows Data to be Exported to Optional FlukeView Temperature PC Software for Further Analysis and Graphing
Technical Specifications:
Accuracy: |
J, K, T, E, and N-type: |
Above -100 C: |
+/- [0.05% + 0.3 C (0.5 F)] R and S-type: +/-[0.05% + 0.4 C (0.7 F)] |
Below -100 C: |
J, K, E, and N-types: +/-[0.20% + 0.3 C (0.5 F)] T-type: +/-[0.50% + 0.3 C (0.5 F)] |
Display Resolution: |
0.1 C / F / K < 1000°; 1C / F / K ³ 1000 |
Measurement Range: |
J-type: -210C to 1200C (-346F to 2192F) K-type: -200C to 1372C (-328F to 2501F) T-type: -250C to 400C (-418F to 752F) E-type: -150C to 1000C (-238F to 1832F) N-type: -200C to 1300C (-328F to 2372F) R/S-type: 0C to 1767C (32F to 3212F) |
Temperature Scale: |
ITS-90 |
Applicable Standards: |
NIST-175 |
Operating Temp: |
-10C to 50C (14F to 122F) |
Storage Temp: |
-40C to 60C (-40F to 140F) |
Humidity: |
0% to 90%; 0C to 35C (32F to 95F) 0% to 70%; 0C to 50C (32F to 122F) |
General Unit Weight: |
400g (14 oz) |
Dimensions: |
6.8 L x 3.4 W x 1.5 D |
Battery: |
3 AA Batteries; Typical 1000-hour life |
Certification: |
CE, CSA, TUV (Pending) |
Safety: |
CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 |
Selection Guide:
Feature |
Model 54 |
Model 53 |
Model 52 |
Model 51 |
T/C Types: |
K,J,T,E,N,R,S |
K,J,T,E,N,R,S |
K,J,T,E |
K,J,T,E | < TR>
Inputs: |
Dual |
Single |
Dual |
Single |
Time Stamp: |
Time of Day |
Time of Day |
Relative |
Relative | < TR>
Rugged Holster: |
|
|
|
|
Sealed Case: |
|
|
|
| < TR>
Backlit Display: |
|
|
|
|
MIN/MAX/AVG: |
|
|
|
| < TR>
Toolpak Option: |
|
|
|
|
Differential Temp: |
|
No |
|
No | < TR>
Data Logging: |
(500 Points) |
(500 Points) |
No |
No |
IR PC Interface: |
|
|
No |
No |
|