Martel TC-100 Thermocouple Calibrator
The Martel TC-100 Thermocouple Calibrator provides high accuracy source and measurement of ten common thermocouples, as well as mV. The TC-100's accuracy of +/-0.3 C for Type J T/Cs includes all errors, at resolutions of +/-0.01 C or F in measure mode and +/-0.1 C or F in source mode. Features including MIN/MAX recall in measure mode, three setpoints per thermocouple range, a large knob for decade control of the output in source mode, and the ability toaccept bare T/C wires in addition to mini-plug inputs, makes the TC-100 an accurate, easy-to-use instrument for all your thermocouple calibration needs.
Features:
High Accuracy - +/-0.3 C (Type J T/C all Errors Combined) Ten (10) Common T/C Types Plus mV Accepts Both T/C Mini-Plug and Bare T/C Wires Simple Decade Control of Output Three (3) Setpoints for each T/C Type MIN/MAX Recall in Measure Mode Input Protection to 240 VAC Passworded User Interface Allows Selction of Only Certain Functions Two Digit Resolution in measure mode ie 100.00 Doubles as a Highly Accurate Thermometer
Technical Specifications (1 year at 23 C +/-5 C; % of reading unless otherwise noted):
Output Voltage |
Range: -10 to +75.000 mV Resolution: 1 µV Accuracy: +/-0.007 % of reading, +/-10 µV Output Impedance: =1 Ohm |
Input Voltage |
Range: -10 to +75.000 mV Resolution: 1 µV Accuracy: +/-0.007 % of reading, +/-10 µV Input Impedance: > 1 MegOhm |
Types: |
J, K, T, E, R, S, B, L, U, C |
Range: |
mV |
Resolution: |
Source +/-0.1 C or F Measure +/-0.01 C or F |
Accuracy: |
J +/-0.5 C; -210 C to -100 C +/-0.3 C; -100 C to +1,200 C K +/-0.6 C; -200 C to -100 C +/-0.35 C; -100 C to +1,000 C +/-0.5 C; +1,000 C to +1,372 C T +/-0.7 C; -200 C to -150 C +/-0.3 C; -150 C to +400 C E +/-0.5 C; -200 C to -100 C +/-0.3 C; -100 C to +1,000 C R +/-1.8 C; 0 C to 250 C +/-1.0 C; 250 C to +1,767 C S +/-1.8 C; 0 C to 250 C +/-1.0 C; 250 C to +1,767 C B +/-1.7 C; 600 C to 1,000 C +/-1.2 C; 1,000 C to 1,820 C L +/-0.5 C; -200 C to -100 C +/-0.4 C; -100 C to +900 C U +/-0.7 C; -200 C to 0 C +/-0.3 C; 0 C to +600 C C +/-0.4 C; 0 to C 1,000 C +/-0.7 C; 1,000 C to +1,800 C +/-1.2 C; +1,800 C to +2,316 C |
CJC Temperature Offset: |
+/-0.05 C/ C outside of 23+/-5 C |
Warm-up Time: |
1 minute to specification |
Environmental: |
Operating -10 C to +55 C Storage -20 C to +70 C |
Power Requirements: |
Battery 9 Volt alkaline; 006P/ IEC 6F22/ NEDA1604 Optional NiCad Optional AC adapter/charger |
Mechanical Dimensions: |
5.7" x 3.15" x 1.43" (14.47 cm x 8.00 cm x 3.63 cm) |
Weight: |
12 ounces (340 grams) |
Notes: |
Temperature Standard ITS-90 |
|