Fluke 54 Series II B Thermometers
Item Number: FLUKE-54-2 B
Manufacturer: FLUKE
Manufacturer Part No: FLUKE-54-2 B
Product Options
* denotes required field
NIST Traceable Calibration*
* Whole number only
|
|
Fluke 54 Series II B Data Logging Digital Thermometer
Fluke 50-II Thermometer Family The new Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3 C) in a rugged, handheld test tool. Features (All Models):
- Large Backlit Dual Display
- Relative Time Clock on MIN, MAX, and AVG
- Electronic Offset Function Improves Overall Accuracy
- Measures J, K, T, and E-types of Thermocouples
- Readout in C, F, or Kelvin (K)
- Splash and Dust Resistant Case
- Protected by Impact Absorbing Holster
- User-friendly Front Panel
- Sleep Mode Increases Battery Life to 1000 Hours
- Separate Battery Compartment
- 3 Year FLUKE Warranty
The Fluke 53 Series II and 54 Series II Also Include: • Data Logging up to 500 Points of Data • User Adjustable Recording Interval • Also Read Type R, S, and N Thermocouples • Real Time Clock Captures the Exact Time of Day when Events Occur • Recall Function Allows Logged Data Review • IR Communication Port Allows Data to be Exported to Optional FlukeView™ Temperature • PC Software for Further Analysis and Graphing
Technical Specifications:
Accuracy: |
J, K, T, E, and N-type: |
Above -100 C: |
+/- [0.05% + 0.3 C (0.5 F)] R and S-type: +/-[0.05% + 0.4 C (0.7 F)] |
Below -100 C: |
J, K, E, and N-types: +/-[0.20% + 0.3 C (0.5 F)] T-type: +/-[0.50% + 0.3 C (0.5 F)] |
Display Resolution: |
0.1 C / F / K < 1000°; 1C / F / K ³ 1000 |
Measurement Range: |
J-type: -210C to 1200C (-346F to 2192F) K-type: -200C to 1372C (-328F to 2501F) T-type: -250C to 400C (-418F to 752F) E-type: -150C to 1000C (-238F to 1832F) N-type: -200C to 1300C (-328F to 2372F) R/S-type: 0C to 1767C (32F to 3212F) |
Temperature Scale: |
ITS-90 |
Applicable Standards: |
NIST-175 |
Operating Temp: |
-10C to 50C (14F to 122F) |
Storage Temp: |
-40C to 60C (-40F to 140F) |
Humidity: |
0% to 90%; 0C to 35C (32F to 95F) 0% to 70%; 0C to 50C (32F to 122F) |
General Unit Weight: |
400g (14 oz) |
Dimensions: |
6.8” L x 3.4” W x 1.5” D |
Battery: |
3 AA Batteries; Typical 1000-hour life |
Certification: |
CE, CSA, TUV (Pending) |
Safety: |
CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 |
Selection Guide:
Feature |
Model 54 |
Model 53 |
Model 52 |
Model 51 |
T/C Types: |
K,J,T,E,N,R,S
|
K,J,T,E,N,R,S
|
K,J,T,E
|
K,J,T,E
|
Inputs: |
Dual
|
Single
|
Dual
|
Single
|
Time Stamp: |
Time of Day
|
Time of Day
|
Relative
|
Relative
|
Rugged Holster: |
•
|
•
|
•
|
•
|
Sealed Case: |
•
|
•
|
•
|
•
|
Backlit Display: |
•
|
•
|
•
|
•
|
MIN/MAX/AVG: |
•
|
•
|
•
|
•
|
Toolpak Option: |
•
|
•
|
•
|
•
|
Differential Temp: |
•
|
No
|
•
|
No
|
Data Logging: |
• (500 Points)
|
• (500 Points)
|
No
|
No
|
IR PC Interface: |
•
|
•
|
No
|
No
|
|
Hard Instrument Carry Case with Pluck Foam to fit your instruments. 100's of sizes & styles available. Call for Details
|
|
FlukeView Forms Version 2.0 Software with cable for Fluke 180 Series multimeters, Fluke 789 ProcessMeter, Fluke 50 Series, Fluke 80 Series, Fluke 45 DMM with Cable.
|
Fluke 51 Series II Thermometers, Single Input
|
OUR PRICE: This unit has been discontinued. Please call (732) 632-6400 for replacement options
Martel TP-KIT Type K Thermocouple Probe Kit in Hard Carry Case
|
Fluke 52 Series II Thermometers, Dual Input
|
Fluke 53 Series II B Data Logging Thermometers, Single Input
| |
|
|