Fluke 707Ex Intrinsically Safe Loop Calibrator
Item Number: FLUKE-707EX
Manufacturer: FLUKE
Manufacturer Part No: FLUKE-707EX
|
|
Fluke 707Ex Intrinsically Safe Loop Calibrator
The 707Ex is an intrinsically safe loop calibrator for use in explosion endangered areas. The Fluke 707Ex is certified in accordance with the ATEX directive (Ex II 2 G Eex ia IIC T4) in Zones 1 and 2. The 707Ex is also certified to operate in accordance with Factory Mutual N.I. Class 1, Division 2 areas Group A-D.
Features:
-
ATEX Intrinsic Safe Certification for use in classified areas
-
Large display, simple one-handed operation
-
Simultaneous mA and % readout for quick readings
-
mA accuracy of 0.015 %, superior to other loop calibrators
-
1 uA resolution for mA source, simulate and measure
-
Push button with 25 % steps for fast, easy linearity checks
-
0-100 % "span check" for fast confirmation of zero and span
-
Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests
-
Internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM
-
Measures V DC to 28 V
-
Single 9 V battery that is easily changed
-
Innovative output adjustment dial with 1 uA and 100 uA resolution
-
HART™ compatible resistance is connected in series with the loop supply for compatibility with HART communicators
Technical Specifications:
Read DC Volts: |
0-28.000 VDC (+/-0.015% Rdg + 2 Cts) |
Read mA: |
0-24.000 mADC (+/-0.015% Rdg + 2 Cts) |
Source mA: |
0-24.000 mADC (+/-0.015% Rdg + 2 Cts) |
Simulate mA: |
0-24.000 mADC (+/-0.015% Rdg + 2 Cts) |
Loop Power: |
0-24 VDC (+/-10%) |
MODES: |
Measure Current Measure Current/Loop Power Measure Voltage Simulate Current; Manual Adjust; Scroll Simulate Current; 25% Steps; 0 - 100% Steps Simulate Current; Auto Ramp (Smooth/Step) Source Current; Manual Adjust; Scroll Up/Down Source Current; 25% Steps; 0 - 100% Steps Source Current; Auto Ramp (Smooth/Step) |
Maximum Voltage: |
30 volts |
Storage Temp: |
-30 to 60 Deg C |
Operating Temp: |
-10 to 55 Deg C |
Relative Humidity: |
0 to 90% (0 to 35 Deg C); |
Operating Altitude: |
3,000 meters max. |
Shock and Vibration: |
Per MIL-T-28800, Class 2 Instrument |
Safety: |
CSA C22.2 No. 1010.1: 1992 ATEX Ex II G ia IIC T4 Zones 1 & 2, ZELM o2 ATEX 0120 X FM N.I. Class 1, Div 2, Groups A, B, C, D CE EN61010-1 and EN61326 |
EMC: |
EN50082-1:1992 and EN55022:1994 Class B |
Size/Eeight: |
6.0"L x 2.8"W x 1.6"D, 8 Ozs. |
Battery: |
One 9V Alkaline |
Battery life: |
18 Hours Typical, at 12 mA |
Warranty: |
Three Years |
|
Hard Instrument Carry Case with Pluck Foam to fit your instruments. 100's of sizes & styles available. Call for Details
|
|
|
|
| |
|
|