Fluke 718Ex Intrinsically Safe Pressure Calibrator
Item Number: FLUKE-718EX
Manufacturer: FLUKE
Manufacturer Part No: FLUKE-718EX
Product Options
* denotes required field
Fluke 718Ex Pressure Range Selection*
You must select an option for 'Fluke 718Ex Pressure Range Selection'.
* Whole number only
|
|
Fluke 718Ex Intrinsically Safe Pressure Calibrator
The Fluke 718Ex Intrinsically Safe Pressure Calibrator offers high performance in an ATEX-compliant pressure calibrator. A complete, self-contained calibration, switch test solution, the 718Ex offers:
- Built-in pressure / vacuum hand pump, with
fine adjust vernier and bleed valve.
- Pressure measurement to 0.05% of full span,
using an internal pressure sensor.
- Pressure measurement to 3,000 psi / 200 bar using any of
eight intrinsically safe Fluke 700PEx Pressure Modules.
- Wide range of selectable measurement units for pressure.
- Current measurement with 0.02% accuracy
and 0.001 mA resolution.
- Pressure switch test function.
- Min-Max Hold functions.
- Compact size and weight.
- Simple, push-button user interface.
- Rugged and reliable, ideal for field use.
- Ships with a NIST traceable calibration certificate.
Technical Specifications:
Function Specifications |
Measure Pressure (internal sensor) Over Pressure 3xFS (718 30G only)* |
Range: -12 to 30 psi (-83 to 207 kPa)
Resolution: 0.001 psi (0.01 kPa)
Accuracy: 0.05% full scale For use with non-corrosive gasses Zero, Min, Max, Hold, Damp |
Measure Pressure (internal sensor) Over Pressure 3xFS (718 100G only) |
Range: -12 to 100 psi (-83 to 690 kPa)
Resolution: 0.01 psi (0.1 kPa)
Accuracy: 0.05% of full scale For use with non-corrosive gasses Zero, Min, Max, Hold, Damp |
Measure Pressure (with intrinsic safe Pressure Modules) Over pressure per pressure module specs |
Range: 7 pressure modules, 10.0 in. H20 to 3,000 psig Resolution: To 0.0001 psi, per Pressure Module specs Accuracy: To 0.05% of full span, per Pressure Module specs Note: Media compatibility per Pressure Module Specs, Zero, Min, Max, Hold, Damp |
Source Pressure, built in pump |
Range: -11 psig to full scale
Resolution: N/A
Accuracy: N/A |
Measure mA |
Range: 0 to 24 mA
Resolution: 0.001 mA
Accuracy: 0.025% + 1 count |
General Specifications |
Operating temperature: |
-10 Deg C to 55 Deg C |
Non-operating temperature: |
-40 Deg C to 60 Deg C |
Relative humidity (% RH operating without condensation): |
95% (10 Deg C to 30 Deg C); 75% (30 Deg C to 40 Deg C); 45% (40 Deg C to 50 Deg C); 35% (50 Deg C to 55 Deg C) |
Operating altitude: |
3,000m max |
Vibration: |
Random, 2g, 5-500 Hz |
Shock: |
1m drop test |
Safety: |
II 1 G EEx ia IIC T4
I.S. Class I Div 1 Groups A-D T4 AEx ia IIC T4
Ta = -10,,aC ¡K +55,,aC
EMC: EN6126 2002-02, Criteria C |
Power: |
Single 9V alkaline battery ANSI/NEDA 1604A or IEC 6LR61 |
Size: |
216 mm L x 94mm W x 66 mm D (8.5 in X 3.72 in x 2.06 in) |
Weight (with holster): |
Approx. 992g (35 oz) |
Display: |
Clear, 5 digit liquid crystal |
Warranty: |
3 years |
|
Hard Instrument Carry Case with Pluck Foam to fit your instruments. 100's of sizes & styles available. Call for Details
| |
|
|