Fluke 112 Multimeter
|
OUR PRICE: Item has been discontinued by Fluke, Call for Replacement Recommendations
Item Number: Fluke 112
Manufacturer: FLUKE
Manufacturer Part No: Fluke 112
|
Fluke 112 True RMS Multimeter
Want to compare sizes? These little meters pack more features than some DMMs twice their size. True-rms ac voltage and current readings, for example. 6000 count resolution. Min/Max/Average. And frequency and capacitance capabilities. Plus they give you an easy-open battery access door. Theyre all CAT III rated for 600V and are protected by a three-year warranty. The 112 model has a backlight and delivers 0.7% basic dc accuracy. The price? Theyre less than you think. Yes, smaller is better. Definitely.
FEATURES:
- True-rms ac voltage and current (Model 111 and 112)
for accurate readings on all waveforms
- 6000 count display provides improved resolution
- Min/Max/Average recording
- Frequency, capacitance & resistance capabilities
- 112 has a backlight to illuminate the screen in dark workspaces
- Easy access battery door to change the battery without
breaking the calibration seal
- Drop protected to 1 meter, 3 Year Warranty
- Holster with probe holders for better test lead management
- Compatible with ToolPak™ magnetic hanging kit
- Compact & lightweight for use on the go
- IEC CAT III 600V Safety Rating
Fluke 110 Series DMM Features
|
|
110 |
111 |
112 |
Basic DC accuracy of 0.7% |
• |
• |
• |
6000 count display |
• |
• |
• |
Manual reading hold for user convenience |
• |
• |
• |
IEC 1010 rating: CAT III 600V |
• |
• |
• |
Compatible with Fluke ToolPak meter hanging kit |
• |
• |
• |
Backlight for measurements in low visibility areas |
|
|
• |
Battery access without breaking the calibration seal |
• |
• |
• |
General Specifications |
AC Amps* |
Range: 3.00A to 10.00A Accuracy: +/- (1.5% of reading plus 3 Cts) Not specified below 3A Crest Factor: <= 3 AC Response: 50 Hz to 500 Hz
|
DC Amps* |
Range: 0.001A to 10.00A (20A overload for 30 seconds) Accuracy: +/-(1.0% of Rdg plus 3 counts)
|
AC Volts |
Range: 300 mV to 600.0V rms Accuracy: +/-(1.0% of Rdg plus 3 counts) AC Response: 50 Hz to 500 Hz
|
DC Volts |
Range: 1 mV to 600.0V Accuracy: +/-(0.7% of reading plus 2 Cts) |
Ohms |
Range: 0.1 Ohm to 40.00 M-Ohms Accuracy: +/-(0.9% of Rdg plus 1 Cts)
|
Capacitance |
Range: 1 nF to 9999 uF Accuracy: +/-(1.9% of Rdg plus 2 Cts) |
Continuity |
Beeper guaranteed on <20 Ohms guaranteed off > 250 Ohms; detects opens or shorts of 250 us or longer |
Frequency |
Range: Voltage Input - 5 Hz to 50 kHz Current Input - 50 Hz to 5 kHz (111 and 112 only) Accuracy: +/-(0.1% of Rdg plus 2 counts)
|
Note |
The 110 Series is not recommended for use with AC current clamps. |
* Not applicable for the 110
|
Additional Information
Fluke 110 Series Extended Specifications
|
Hard Instrument Carry Case with Pluck Foam to fit your instruments. 100's of sizes & styles available. Call for Details
|
|
|
|
|
The Fluke PV350 Allows any Multimeter to Read Vacuum and Pressure
|
|
|