Hart Scientific Model 5612 SPRT Temperature Probe (3/16" x 9") -200 to 400 Deg C
|
OUR PRICE: DISCONTINUED CALL FOR REPLACEMENT
Item Number: 5612
Manufacturer: Hart Scientific
Manufacturer Part No: 5612
|
Hart Scientific Model 5612 SPRT Temperature Probe
Features
|
Affordable wide-range accuracy
|
Excellent stability
|
Reference-grade platinum sensing element
|
Specifications
|
Resistance
|
Nominal 100 Ohm (+/-0.1 Ohm)
|
Temperature Coefficient
|
0.003925 ohms/ohm/°C nominal
|
Temperature Range
|
-200°C to 420°C (transition and cable temperature 150°C maximum)
|
Transition Temperature
|
5°C to 200°C
|
Drift Rate
|
+/0.01°C at 0°C per year maximum, when used periodically to 400°C
|
Sheath Material
|
Inconel™ 600
|
Leads
|
Teflon™-insulated, silver-plated stranded copper, 22 AWG
|
Termination
|
Four gold-plated spade lugs are standard. Other options available. See Ordering Information.
|
Hysteresis
|
< 0.01°C at 0°C using -196°C and 420°C as the end points
|
Immersion Effects
|
Reading will not vary more than 0.005°C when the probe immersion is varied between 4 inches and 10 inches in an ice bath (5614).
|
Calibration
|
Includes NIST-traceable calibration and table with R vs. T values in 1°C increments from -183°C to 500°C. The 5614 and 5612 are calibrated to 420°C and the 5613 to 300°C. ITS-90 coefficients included.
|
Probe Accuracy (includes calibration uncertainty and short-term stability)
|
+/-0.018°C at -196°C +/-0.018°C at 0°C +/-0.019°C at 200°C +/-0.023°C at 420°C
|
Time Constant
|
Nine seconds typical for 63.2% response to step change in temperature in water flowing at 3 feet per second
|
Size: 5612 5613 5614
|
0.187" dia. x 9" 0.187" dia. x 6" 0.25" dia. x 12"
|
High Flexibility Cable Option
|
Standard 5612, 5613, and 5614 PRTs come with a 6-foot white Teflon cable that withstands temperatures from -100°C to 250°C. For super-flexible black PVC cable that can be exposed to temperatures from 0°C to 90°C, add “-B” to the model number. (A 5614 PRT with spade lug terminations and PVC cable would be ordered as “5614-S-B.”) No additional charge is added for PVC cable.
|
Need a durable but accurate sensor for use in the factory, field, or lab? The Model 5614 Secondary Temperature Standard is the answer.
The 5614 is a Platinum Resistance Thermometer (PRT) that's 12 inches long with an Inconel 600 sheath and a 1/4" outside diameter. It is designed to be used as a transfer device from the highest laboratory standards to industrial or second-tier lab locations. It has short-term accuracy of +/-0.02°C at 200°C.
The element is constructed of reference-grade platinum wire (99.999% pure) for excellent stability. The wire is wound in a coil and placed in a mandrel where it is uniformly supported in a manner to virtually eliminate hysteresis. The electrical configuration is a four-wire current-potential hookup to eliminate effects of lead-wire resistance.
These Inconel-sheathed probes have a partially supported sensing element, making them more durable than SPRTs. The element is protected in an ultrahigh-purity ceramic case with a hermetic glass seal to improve output stability by locking out moisture and contaminants.
This probe comes calibrated in accordance with ITS-90, which makes it compatible with many excellent readout devices, including Hart's family of advanced readout devices. It bridges the gap between a 100-ohm industrial RTD and an SPRT.
For those needing faster thermal response, or where diameter and immersion depth are problems, order the 6-inch 5613 or the 9-inch 5612. These probes are excellent reference probes for comparison calibrations in a Hart dry-well.
A printout of sensor resistance is provided in 1°C increments for each probe. The 5614 and 5612 are calibrated from -196°C to 420°C. The 5613 is calibrated to 300°C.
We've tested many of the probes on the market. We've used them in our manufacturing facility and tested them in the lab, and this is an excellent secondary standards PRT. Other instruments on the market are priced much higher, have lower stability, or have lower quality.
Remember, these instruments are inexpensive and have excellent durability. Each probe is individually calibrated and includes a report of calibration from the manufacturer.
|
OUR PRICE: Discontinued, Replaced by Fluke 7526A
Martel M2001 Benchtop Multifunction Calibrator
|
OUR PRICE: This unit has been discontinued. Please call (732) 632-6400 for replacement options
Hart Scientific 1521 Standard Thermometer Reads PRTs & Thermistors
|
OUR PRICE: This unit has been discontinued. Please call (732) 632-6400 for replacement options
Hart Scientific 1522 Standard Logging Thermometer Reads PRTs & Thermistors
|
Fluke - Hart Scientific 1502A-156 Tweener Thermometer Readout for RTD, PRT, and Thermistor Sensors
|
Hart Scientific 1529 Chub-E4 Super Thermometer reads four sensor simultaneously with extremely high accuracy
| |
|
|