| | |
|
| |
| | |
|
|
Fluke 85-III True Multimeter
|
OUR PRICE: Discontinued, Replaced by Fluke 87-5
Item Number: Fluke-85
Manufacturer: FLUKE
Manufacturer Part No: 85
|
Fluke 85 Multimeter
The Fluke 80 Series Multimeter, a Standard...
The most versatile meters on the market just got better. Since their introduction, Fluke 80 Series digital multimeters (DMMs) have led the industry in versatile performance, accuracy, and rugged durability. Now the new Fluke 80 Series III DMMs push that lead even further. With a host of new features that increase accuracy, improve safety, and make the 80 Series III easier than ever to use. Look at everything the new 80 Series III has to offer:
- An LED backlight on all models
- New LCD display with larger digits and better viewing angle
4 1/2-digit resolution to detect subtle changes (Model 87, 87/E)
- MIN/MAX to record the minimum, maximum, and average reading over time.
The 87 III and 87/E now offer 250 µS peak MIN/MAX for peak transient capture
- Significantly improved basic dc accuracy on all models
- CAT III 1000V safety rated to withstand overvoltage transients up to 8 kV
- Seprate Battery Compartment does not break the calibration seal
|
Model 83: With a 4000-count digital display that updates 4 times per second, the Model 83 has DC accuracy of 0.3%, plus the ability to measure frequency duty cycle, and capacitance. It also provides a 43-segment, high resolution analog bargraph, TouchHold™, Relative, MIN/MAX Average Recording, MIN/MAX Alert™, and Zoom modes. Model 85: The 80 Series meter with overall best accuracy in AC voltage and current, plus increased DC accuracy over the Model 83. With all the features and functions of the Model 83, the Fluke 85 also has DC Voltage accuracy of 0.1% Model 87: A True-RMS AC voltage and current meter with a 4.5 high resolution mode (19,999 counts), the Fluke 87 stands apart by the number of features and functions it offers. In addition to true-rms, these include 1 ms Peak Min/Max Hold and a high resolution analog pointer for changing or unstable signals. Only the 87 has a backlit display, enabling clear readings in poorly lit settings. The light shuts off after 68 seconds, prolonging battery life.
|
FEATURES:
- Min/Max
- Store Min/Max/Avg for 36 Hours
- 43 Segment Bar Graph Display
- TouchHold™
- Lifetime Warranty
-
4000 Counts
- UL 1244 Listed
- Store Min/Max/Avg for 36 Hours
- EMI Shielded
- Store Min/Max/Avg for 36 Hours
SPECIFICATIONS:
MODEL: |
Fluke 83 |
Fluke 85 |
Fluke 87 |
V DC (40.0mV to 1000V): |
(+/-0.3%+1) |
(+/-0.1%+1) |
(+/-0.1%+1) |
V AC (400mV - 1000V): |
(+/-1.0%+3) |
(+/-0.5%+2) |
(+/-0.7%+2) |
A DC (400µA -10A): |
(+/-0.4%+3) |
(+/-0.2%+3) |
(+/-0.2%+3) |
A AC (400µA -10A): |
(+/-1.2%+2) |
(+/-0.6%+2) |
(+/-1.0%+2) |
Resistance (400 - 40 MOhms): |
(+/-0.4%+1) |
(+/-0.2%+1) |
(+/-0.2%+1) |
Conductance (40 nS): |
(+/-1.0%+10) |
(+/-1.0%+10) |
(+/-1.0%+10) |
Capacitance (5nF - 5µF): |
(+/-1.0%+2) |
(+/-1.0%+2) |
(+/-1.0%+2) |
Frequency (199.99 - 199.9 kHz): |
(+/-1.0%+2) |
(+/-1.0%+2) |
(+/-1.0%+2) |
Diode/Continuity Test: |
Yes |
|
|
Size: |
7.35 x 3.41 x 1.25" |
7.35 x 3.41 x 1.25" |
7.35 x 3.41 x 1.25" |
Weight: |
12.5Oz. |
12.5Oz. |
12.5Oz. |
Each Meter includes a 9v battery, test leads, ruber holster with stand and manual What is "Limited Lifetime Warranty"? Each Fluke 20, 70, 80, 170 and 180 series DMM will be free from defects in material and workmanship for its lifetime. As used herein, "lifetime" is defined as seven years after Fluke discontinues manufacturing the product, but the warranty period shall be at least ten years from date of purchase.
In what way is the warranty limited?
- It does not cover battery or fuses.
- It does not cover abuse or usage outside of specifications.
- It does not cover normal wear and tear of mechanical parts.
- It covers the LCD for 10 years only (state-of-the-art for LCDs).
- It covers original user purchaser only
|
Hard Instrument Carry Case with Pluck Foam to fit your instruments. 100's of sizes & styles available. Call for Details
|
|
|
|